Loading...
Loading...
Loading...
Empowering Healthcare, Delivering Trust.

sales@vdbiomedisystems.in

9909993803

VD Bio Medisystems (VD-8M) 5 Para Cardiac Monitor

VD Bio Medisystems (VD-8M) 5 Para Cardiac Monitor

Medical Grade Product SKU: #14

โ‚น25,698 โ‚น36,712 (30% OFF)

Physical Characteristic Display Type : 8 Built-in color TFT / LCD screen , Weight : Around 5 kg ,
Estimated Delivery: 3 - 5 Working Days Across India
Warranty: 1 Year Warranty Official Brand Warranty Included
Guaranteed Safe And Secure Checkout
Secure Payment Gateways

Introduction & Features

  • High resolution 8โ€ color TFT display
  • 6 Parameters : ECG HR Resp NIBP SpO2 TEMP
  • Light weight compact and portable
  • Built-in rechargeable lithium battery
  • Unique human voice alarm
  • Rich screen layouts: Standard Big font Trend table NIBP trend ECG full lead OxyCRG IoC Layout
  • Powerful storage: Maximum 720 Hour graphic and tabular trends of all
  • parameters up to 10000 NIBP review 200alarm review 2Hours of all waveforms
  • System software can be upgraded through network
  • Data and waveforms color be adjustable
  • Arrhythmia analysis and S-T segment analysis
  • Suitable for adult paediatric and neonatal patient

Technical Specifications

  • ECG
  • Lead Mode 5 Leads ( R L F N C or RA LA LL RLV)
  • Lead selection I II III avR avL avF V
  • Waveform 2 ch
  • Lead mode 3 Leads ( R L F or RA LA LL)
  • Lead selection I II III
  • Waveform 1 ch
  • Gain x2.5mm/mV x5.0mm/mV x10mm/mV x20mm/mV auto
  • HR and Alarm
  • Range
  • Neo/Ped 15 ~ 350 bpm
  • Accuracy ยฑ 1% or ยฑ 1bpmwhich great
  • Resolution 1 bpm
  • Sensitivity > 200 (uV )
  • Differential Input Impedance > 5 Mฮฉ
  • CMRR
  • Monitor > 105 dB
  • Operation > 105 dB
  • Diagnosis > 85 dB
  • Electrode offset potential ยฑ300mV
  • Leakage Current < 10 uA
  • baseline Recovery < 3 S After Defi.
  • ECG Signal Range ยฑ8 m V ( Vp-p )
  • Bandwidth
  • Surgery 1 ~ 15 Hz
  • Monitor 0.5 ~ 35 Hz
  • Diagnostic 0.05 ~ 100 Hz
  • Calibration Signal 1 (mV ) Accuracy ๏ผšยฑ5%
  • ST Segment Monitoring Range
  • Measure and Alarm -2.0 ~ +2.0 mV
  • ARR Detecting
  • Type ASYSTOLE VFIB/VTAC COUPLET BIGEMINY TRIGEMINY R ON T VT>2 PVC TACHY BRADYMISSED BEATS PNP PNC
  • Alarm Available
  • Review Available
  • RESPARATION
  • Method Impedance between R-F(RA-LL)
  • Differential Input Impedance >2.5 Mฮฉ
  • Measuring Impedance Range: 0.3~5.0ฮฉ
  • base line Impedance Range: 0 โ€“ 2.5 Kฮฉ
  • Bandwidth 0.3 ~ 2.5 Hz
  • Resp. Rate
  • Measuring and Alarm Range
  • Adult 0 ~ 120 rpm
  • Neo/Ped 0 ~ 150 rpm
  • Resolution 1 rpm
  • Accuracy ยฑ2 rpm
  • Apean Alarm 10 ~ 40 S
  • NIBP
  • Method Oscillometric
  • Mode Manual Auto STAT
  • Measuring Interval in AUTO Mode 1 2 3 4 5 10 15 30 60 90 120 180 240480 (Min)
  • Measuring Period in STAT Mode 5 Min
  • Pulse Rate Range 40 ~ 240 bpm
  • Alarm Type SYS DIA MEAN
  • Measuring and alarm range
  • Adult Mode
  • o SYS 40 ~ 270 mmHg
  • o DIA 10 ~ 215 mmHg
  • o MEAN 20 ~ 235 mmHg
  • Pediatric Mode
  • o SYS 40 ~ 200 mmHg
  • o DIA 10 ~ 150 mmHg
  • o MEAN 20 ~ 165 mmHg
  • Neonatal Mode
  • o SYS 40 ~ 135 mmHg
  • o DIA 10 ~ 100 mmHg
  • o MEAN 20 ~ 110 mmHg
  • Resolution
  • o Pressure 1mmHg
  • o Accuracy
  • o Pressure
  • Maximum Mean error ยฑ5mmHg
  • Maximum Standard deviation ยฑ8mmHg
  • Overpressure Protection
  • o Adult Mode 297ยฑ3 mmHg
  • o Pediatric Mode 240ยฑ3 mmHg
  • o Neonatal Mode 147ยฑ3 mmHg
  • SpO2
  • Measuring Range 0 ~ 100 %
  • Alarm Range 0 ~ 100 %
  • Resolution 1 %
  • Accuracy 70% ~ 100% ยฑ2 %
  • o 0% ~ 69% unspecified
  • Actualization interval about 1 Sec.
  • Alarm Delay 10 Sec.
  • Pulse Rate
  • Measuring and Alarm Range 0~254bpm
  • Resolution 1bpm
  • Accuracy ยฑ2bpm
  • TEMPERATURE
  • Channel 1
  • Measuring and Alarm Range 0 ~ 50 C
  • Resolution 0.1~C
  • Accuracy ยฑ0.1~C
  • Actualization interval about 1 Sec.
  • Average Time Constant < 10 Sec.
  • IBP
  • Label ART PA CVP RAP LAP ICP P1 P2
  • Measuring and alarm range
  • ART 0 ~ 300 mmHg
  • PA -6 ~ 120 mmHg
  • CVP/RAP/LAP/ICP -10 ~ 40 mmHg
  • P1/P2 -10 ~ 300 mmHg
  • Press Sensor
  • Sensitivity 5 uV/V/mmHg
  • Impedance 300-3000ฮฉ
  • Resolution 1 mmHg
  • Accuracy ยฑ2% or ยฑ1mmHg which great about 1 Sec.

Performance & Parameters

  • Display & Interface: Equipped with a bright 8.4-inch high-resolution color TFT LCD display, allowing for intuitive reading of clinical data.
  • Parameters Measured: Continuously monitors ECG, RESP (respiration), NIBP (non-invasive blood pressure), SpOโ‚‚ (blood oxygen), and Temperature.
  • Cardiac Assessment: Features real-time S-T segment analysis, arrhythmia detection, and multi-lead ECG waveform display, making it suitable for basic cardiac monitoring.
  • Power & Portability: Operates on an input voltage of 220โ€“240V and includes a built-in rechargeable lithium battery for reliable backup during power outages or patient transport.
  • Patient Versatility: Designed to safely monitor adult, pediatric, and neonatal patients.

Content In Box & Accessories

  • ECG Cable (5 Leads) ...... 1Pcs
  • SpO2 Cable (Adult) ........ 1Pcs
  • TEMP Probe (Adult) ....... 1Pcs
  • NIBP Cuff (Adult) ............ 1Pcs
  • NIBP Tube(150cm) ......... 1Pcs
  • Ground Cable ................ 1Pcs
  • Power Cable ................... 1Pcs
  • Cleaning Cloth ................ 1Pcs
VD BIO MEDISYSTEMS

VD BIO Medisystems is a leading importer, manufacturer, and supplier of high-quality medical equipment and accessories. We are dedicated to providing innovative and reliable healthcare solutions worldwide.

+91 99099 93803

U-31 , Kashi Plaza , Opp. Signet Mall , Kamrej Chowk , Kamrej , Surat , Gujarat 394180

sales@vdbiomedisystems.in

vdbiomedisystems@gmail.com

© 2026 VD BIO Medisystems. All Rights Reserved.

Designed & Distributed by Browin Technology
100% Secure Payments Powered By Razorpay